Purify the Material and Measure the Remaining Metals
Discuss a Purification or Trace Metal ProjectPLUS combines high-purity separation and purification development with trace metal control and ICP-MS analysis. Purification changes the impurity profile; ICP-MS measures elemental impurities. ICP-MS is an analytical technique, not a purification process.
Customer challenges
An assay result does not establish a low-metal specification. Organic impurities, elemental impurities and contamination introduced during sampling or packaging need different controls. A non-detect result is meaningful only with its method and reporting limit.
Project scope
Discuss purification of defined crude or off-spec materials, comparison of feed and purified samples, a target-element panel and investigation of possible metal sources. Separation options are selected only after reviewing volatility, solubility, thermal stability and impurity properties; no particular unit operation or equipment configuration is promised here.

What to send
Provide composition and sample matrix, solvent and acid content, hazards, current assay and impurity data, target elements and individual limits with units, material quantity and recovery priorities. State whether results are required on an as-received or another defined basis.
Discuss a Purification or Trace Metal ProjectProject workflow
- Review matrix and specification
- establish baseline analysis
- assess separation options
- run purification trials
- analyze paired samples
- review recovery and impurity changes
- agree acceptance criteria and contamination controls for further work
Analytical plan
For ICP-MS, agree sample preparation, target elements, dilution and reporting basis, blank controls, calibration and relevant quality-control checks. Matrix effects and spectral interference must be considered. Detection and quantification limits are element- and matrix-dependent and must be confirmed for the agreed method.
Potential deliverables
Possible outputs include purified evaluation material, before-and-after data, a recovery summary and an ICP-MS report identifying the sample, elements, units, method basis and reporting limits. CoA content and any supporting raw data must be agreed separately.
Frequently asked questions
Does ICP-MS remove metals?
No, it measures elemental impurities.
Does a high chromatographic purity mean low metals?
No, these are separate measures.
Can you guarantee ppt performance for every sample?
No; limits depend on preparation, matrix, element and method capability.
Can you analyze every sample directly?
No. Compatibility, hazards, solubility and matrix load require review.
Can you report zero metals?
No. Results below a reporting limit do not prove absolute absence.
Is third-party testing included?
Only if the scope, provider and costs are agreed.