What exactly is the target?
Chemical name, CAS, structure, drawing, reference sample
Custom Chemical Synthesis for Demanding Specifications
Submit a Custom Synthesis InquiryFrom target molecule assessment and synthetic route development to process optimization and purification, PLUS works with customers to develop practical chemical solutions for specialty and advanced applications.
Whether you need a compound that is not commercially available, an existing route that needs improvement, or a fluorinated or electronic chemical intermediate with defined purity requirements, start by sharing your target structure, CAS number, specification, or project objective.
Standard catalogue chemicals are suitable for many routine requirements, but they may not cover every molecular structure, impurity specification, quantity, or application. A custom synthesis project can be considered when:
Custom synthesis is not simply making a molecule to order. It requires agreement on what the target product must be, how it will be evaluated, and what level of process development is needed to deliver it consistently.

Chemical name, CAS, structure, drawing, reference sample
Purity, impurity limits, moisture, halogen and anion content, residual solvents, trace metals, analytical method
Sample amount, initial batch, annual forecast
Semiconductor/electronics, battery, thermal management, pharmaceutical intermediate, other
Sample target date, required delivery date, project milestones
Existing route, process notes, chromatograms, specification, SDS
NDA, background IP, project results, permitted use
We review the target structure and the customer's required product attributes before defining the development route. The review may identify structural ambiguities, stereochemical requirements, salt or solvate form, key impurities, physical properties, and analytical requirements that need clarification.
Customer input: structure or CAS number, target specification, intended application, and any available reference data.
Potential output: a clarified target profile and a list of technical questions or information gaps for the feasibility review.
Potential routes are reviewed in relation to starting material availability, reaction sequence, selectivity, expected impurity risks, safety, work-up, purification, and potential scale-up constraints. Where appropriate, alternative routes may be compared before a development plan is proposed.
Potential output: a route assessment, identified technical risks, key assumptions, and a recommended next stage. A route assessment is not a guarantee of successful synthesis; experimental verification may be required.
Development work may include laboratory trials, reaction-condition screening, reagent and solvent assessment, reaction monitoring, work-up evaluation, and yield or selectivity improvement. The experimental plan should be proportionate to the project's objective and agreed budget.
Potential output: intermediate or target samples where agreed, and a summary of remaining development needs.
For suitable projects, PLUS can discuss the development of fluorinated compounds and related intermediates, drawing on its technical focus in electrochemical fluorination. Project review should consider the target fluorination pattern, substrate compatibility, starting materials, reaction selectivity, process safety, purification route, and final product specification.
Potential output: a project-specific technical assessment and, if accepted, an agreed development plan. The feasibility of each fluorination project depends on the specific molecular structure and process requirements.
The target material is assessed against the agreed purity and impurity requirements. Development may include selection of an isolation method, purification-condition evaluation, removal of process-related impurities, and review of the resulting analytical profile.
Potential output: purified sample where agreed, analytical results within the agreed scope, and recommendations for further purification or specification adjustment if needed.
The exact stages may vary. A small intermediate synthesis may not require every stage, while a new and technically complex compound may need additional route research, experiments, or scale-up validation.
A custom synthesis quotation is based on the defined scope, not only on the weight of the final product. Key cost drivers may include:
For this reason, two projects requiring the same final quantity may have very different costs. A small quantity of a new, difficult-to-synthesize compound can require more development work than a larger quantity of a well-established intermediate.
Project timing depends on the chemistry and the agreed deliverables. Factors may include raw material lead time, route complexity, number of experiments, reaction duration, purification development, analytical testing, customer review, and production scheduling.
An estimated timeline should be discussed after the initial technical review. If the customer has a fixed deadline, this should be stated at the inquiry stage so that feasibility and schedule risks can be considered early.
Custom synthesis projects may involve unpublished structures, proprietary routes, customer-supplied materials, or commercially sensitive specifications. Before confidential information is exchanged, the parties can discuss the appropriate confidentiality arrangements, including an NDA where agreed.
The project agreement should distinguish between each party's pre-existing intellectual property and know-how, project-specific results, permitted use, disclosure restrictions, and ownership or licensing arrangements. These terms should be settled before development work begins, rather than assumed.

Custom synthesis and process development for selected electronic and semiconductor chemical requirements, including high-purity specifications and trace-metal control.
Project-based development of fluorinated compounds, subject to structure and process feasibility.
Customized development of selected specialty battery chemicals and intermediates.
Selected pharmaceutical intermediates and non-GMP chemical development projects.
Please share the target compound name or CAS number, molecular structure if available, required quantity, target purity, intended application, and requested delivery date. Existing synthesis routes, product specifications, analytical methods, reference samples, or impurity requirements are also helpful. You do not need to have every detail ready for the first inquiry; we can identify any information gaps during the initial review.
Projects involving compounds that are not available from standard suppliers may be considered for custom synthesis. We review the target structure, starting material availability, potential route, safety considerations, purification requirements, and target specification before confirming whether the project is suitable.
Route development may be included when a suitable route is not available or an existing route does not meet the project requirements. Depending on the molecule, the work may include literature and route research, starting material assessment, reaction screening, route comparison, and experimental verification. The scope and deliverables are agreed before work begins.
Yes, an existing route can be reviewed for potential improvement. Depending on the process, optimization may focus on reaction conditions, yield, selectivity, reagent or solvent selection, impurity formation, work-up, isolation, purification, reproducibility, and manufacturing practicality.
Fluorinated compounds and electrochemical fluorination are important technical areas for PLUS. Each project is reviewed according to the target structure, required fluorination pattern, substrate compatibility, starting materials, process safety, purification needs, and product specifications. Please provide a structure or CAS number for an initial technical discussion.
PLUS prioritizes selected semiconductor and electronic chemical requirements, including project-based development of electronic chemical intermediates, fluorinated specialty compounds, and selected photoresist-related monomers or resin monomers. The exact scope depends on the target molecule, purity requirements, analytical methods, and manufacturing feasibility.
PLUS considers selected specialty battery chemical and additive projects. Feasibility depends on the molecular structure, required performance and purity specifications, synthesis route, raw material availability, and requested quantity. Please share the target compound and intended battery application so the technical requirements can be reviewed.
A CAS number is a useful starting point, but it may not define every project requirement. We may also need the required grade, purity, impurity limits, quantity, application, and any specific analytical or packaging requirements. If the CAS number refers to multiple forms or specifications, these should be clarified before quotation.
Sample preparation may be included in the agreed project scope, subject to technical feasibility, material availability, safety review, and the required quantity. Sample specifications, analytical testing, cost, packaging, and delivery arrangements should be agreed before preparation.
The achievable purity depends on the compound, synthesis route, impurity profile, stability, and available purification and analytical methods. Please provide your target purity and, where possible, the key impurity limits and test method. We can then assess whether the specification appears technically achievable and what development may be required.
Trace metal and other impurity requirements—including moisture and halogen content—can be reviewed as part of the product specification. Where applicable, ICP-MS-based analysis may support the evaluation of selected trace elements. PLUS has Class 100 and Class 1,000 cleanroom facilities and is equipped with an Agilent 8900 ICP-MS/MS and an Agilent 7850I ICP-MS. The target elements, sample matrix, analytical method, detection or quantification limits, and reporting basis must be confirmed for each project.
Depending on the compound and specification, analytical techniques may include HPLC, LC-MS, GC, GC-MS, NMR, MS, and ICP-MS. Testing may also cover moisture content, anion content, viscosity, density, boiling point, residue, evaporation rate or loss on drying, dielectric constant, dielectric strength, flash point, and pour point. The method selection depends on the sample matrix, required parameters, and method availability. Required methods and acceptance criteria should be agreed before the project starts.
Scale-up may be evaluated after the laboratory route and available process data have been reviewed. Key considerations include reaction performance, heat and mass transfer, mixing, process safety, impurity profile, equipment compatibility, raw material supply, and target batch size. Not every laboratory route can be transferred directly without further development.
Feasible quantities vary by compound and process. They depend on reaction characteristics, equipment compatibility, safety requirements, purification capacity, raw material supply, and production scheduling. Our capabilities can range from gram-scale development batches to annual production volumes at the thousand-tonne level, depending on the product and process. Please provide both the immediate requirement and any expected repeat or annual demand so the appropriate production route can be assessed.
Lead time depends on route complexity, raw material availability, development work, purification, analytical testing, sample review, and production scheduling. After the technical scope is understood, an estimated schedule and milestones can be discussed. A timeline should be confirmed for each project rather than assumed from a general standard.
Pricing may reflect route complexity, number of steps, raw materials and reagents, development effort, expected yield, purification difficulty, analytical requirements, quantity, packaging, and delivery conditions. A meaningful quotation requires a sufficiently clear target specification and project scope.
MOQ is project-specific. It may depend on raw material purchasing conditions, batch setup, process requirements, purification, packaging, and the quantity needed for meaningful quality testing. Please share the requested sample and order quantities so we can assess the most practical arrangement.
Confidentiality requirements can be discussed before sensitive information is exchanged. An NDA may be reviewed and signed subject to mutual agreement and company procedures. Customers should identify confidential structures, process information, samples, and restrictions on disclosure or use at the beginning of the discussion.
Ownership and permitted use should be defined in the project agreement. The agreement should distinguish pre-existing technology and know-how from project-specific results, and clarify ownership, licensing, disclosure, and use restrictions. These terms should be agreed before work begins.
Depending on the product and agreed scope, documentation may include a Certificate of Analysis (CoA), Safety Data Sheet (SDS), analytical report, product specification, and relevant batch records. The exact documents and format should be confirmed during quotation and project planning.
PLUS's current pharmaceutical-related scope focuses on selected intermediates and non-GMP projects. GMP manufacturing is not currently offered. If your project requires GMP production, please identify this requirement at the inquiry stage so that the project scope can be assessed accurately.
Repeat production may be discussed when the process, quality requirements, raw material strategy, and manufacturing feasibility have been established. Long-term supply planning should consider demand forecasts, batch size, lead time, change control, quality documentation, and commercial terms.










From specialty chemical sourcing to custom synthesis and manufacturing, we're ready to discuss your requirements.