Analytical & Quality Support

Know What Is in Your Product — and Whether It Meets the Specification

Discuss Your Purity and Analytical Requirements

For high-purity and specialty chemicals, a purity percentage alone may not provide enough information. Customers may need to confirm product identity, individual impurities, trace metals, moisture, halogen and anion content, residual solvents, or batch-to-batch variation.

PLUS approaches analytical and quality requirements as part of the project specification. We discuss which attributes matter for the customer's application, which analytical methods are appropriate, what acceptance criteria should apply, and what documentation is required for sample review or product delivery.

Purity Is Only One Part of the Specification

A product specification may include several independent quality attributes. Depending on the application, these may include:

  • Chemical identity and composition.
  • Assay or chromatographic purity.
  • Specific organic or inorganic impurities.
  • Trace elemental or metal impurities.
  • Residual solvents and water content.
  • Physical properties such as appearance, color, or phase.
  • Stability and storage conditions.
  • Packaging compatibility and contamination control.

The customer and supplier should agree on the test method and acceptance criteria for each critical attribute. A statement such as “99.9% purity” should be supported by a defined analytical method and a clear basis of calculation.

Trace Metal Analysis and ICP-MS

For selected high-purity chemical applications, trace elemental impurities may be a critical part of the product specification. ICP-MS can be used, where available and suitable for the sample matrix, to evaluate selected trace elements at low concentrations.

A useful trace-metal specification should identify:

  • Which elements must be measured.
  • The limit for each element or the total elemental impurity requirement.
  • Sample preparation and analytical method.
  • Detection limit (LOD) or quantification limit (LOQ), where relevant.
  • Whether results are reported by mass, concentration, or another agreed basis.
  • Sampling and contamination-control requirements.

The achievable analytical range depends on the instrument, method, sample matrix, blank levels, sample preparation, and method validation. Therefore, specific detection limits should only be quoted after the analytical method and sample type have been reviewed.

Analytical Methods and Reporting

Depending on the compound and the question being answered, relevant analytical techniques may include HPLC, LC-MS, GC, GC-MS, NMR, MS, and ICP-MS. Product-specific testing may also cover moisture content, anion content, viscosity, density, boiling point, residue, evaporation rate or loss on drying, dielectric constant, dielectric strength, flash point, and pour point. These methods and tests are not interchangeable: each provides different information and has different limitations.

Before testing, the project should define the purpose of each method, sample requirements, reporting format, acceptance criteria, and whether the method is suitable for routine batch release or only for development-stage characterization.

Where customer-specific methods are required, the method, reference standard, sample preparation, and data interpretation should be agreed before testing.

Quality Documentation and Batch Review

Depending on the agreed scope and product requirements, documentation may include a Certificate of Analysis (CoA), Safety Data Sheet (SDS), analytical report, product specification, and relevant batch records.

A CoA should be linked to the relevant batch and report the agreed test items and results. Any customer-specific format, additional test, or special statement should be reviewed before the quotation is finalized.

Scale-Up & Analytical Support – Additional FAQs

Can every laboratory process be scaled up directly?

No. A laboratory process may need further evaluation or optimization before scale-up. Heat transfer, mixing, mass transfer, reaction safety, impurity formation, equipment compatibility, and purification can change with scale.

What information is needed for a scale-up assessment?

Useful information includes the laboratory procedure, batch size, reaction conditions, material balance, analytical results, known safety information, raw material specifications, and the target production quantity.

Can you manufacture according to our existing specification?

An existing specification can be reviewed as the starting point. The parties should confirm whether the test methods, impurity limits, sampling plan, packaging, and acceptance criteria are technically practical and mutually understood.

Can you guarantee the same quality for every batch?

Batch consistency depends on process control, raw material variation, equipment, sampling, analytical methods, and defined acceptance criteria. The appropriate controls should be established and verified for the specific product and process; absolute guarantees should not be made without supporting data.

Can you provide a CoA and SDS?

The availability and format of a CoA, SDS, and other agreed documents should be confirmed for the specific product and project. A CoA should reflect the agreed test items and actual batch results.